TRANSFORMER (380V THREE WIRE MODELS ONLY)

SERVICE (cont.)

TRANSFORMER (380V THREE WIRE MODELS ONLY)

P1752.55

FIG. 34 TRANSFORMER

Location:

The transformer is located on the top rear of the timer mounting bracket.

Test Procedures:

1.Disconnect the brewer from the power source.

2.Disconnect black wire and the red wire from the terminal block at the transformer.

3.With a voltmeter, check the voltage across the black wire and the red wire. Connect the brewer to the power source. The indication must be 380 volts ac.

4.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to wiring diagram and check the brewer wiring harness.

5.Reconnect the black wire and the red to the trans- former.

6.Disconnect the black wire and the white wire from the transformer terminals.

7.With a voltmeter, check the voltage across the transformer terminals. Connect the brewer to the power source. The indication must be 120 volts ac.

If voltage is present as described, the transformer is operating properly

If voiltage is not present as described, replace the transformer.

Removal and Replacement:

1.Disconnect all the wires from the transformer.

2.Remove the two #8-32 screws securing the trans- form to the transformer mounting bracket.

3.Remove the transformer and discard.

4.Position new transformer on transformer mounting bracket and secure with two #8-32 screws.

5.Refer to Fig. 35 and reconnect the wires.

RED from

WHI from Main

 

Terminal Block

 

Harness

 

 

 

BLK from

BLK from

 

Terminal Block

Main Harness

 

FIG. 35 TRANSFORMER TERMINALS

P1753

 