SERVICE (cont.)
LIQUID LEVEL BOARD AND LEVEL PROBE (cont.)
9.Reconnect the pink wire to terminal 4.
10.Remove the two
11.Gently pull the probe out of the component bracket
and inspect for corrosion. Replace if necessary.
12 Place the probe so that neither end is in contact with any metal surface of the brewer.
13.Connect the brewer to the power source. Check the voltage across terminals 1 and 3, refer to chart below. There is an approximate delay of five seconds for output to stabilize.
Model | Voltage - | Voltage - |
| Jumper | Jumper |
| Not Touching | Touching |
| Frame | Frame |
120/208V & | 120V | 0 |
120/240V - 3 |
|
|
wire w/ground |
|
|
single phase |
|
|
230V - 2 wire | 230V | 0 |
w/ground |
|
|
single phase |
|
|
208V or 240V - | 208V or | 0 |
2 wire wground | 240V | 0 |
single phase |
|
|
280V or 440V - | 220V or | 0 |
4 wire w/ground | 254V | 0 |
3 phase |
|
|
380V - 3 wire | 120V | 0 |
w/ground 3 |
|
|
phase w/ stepdown trans- former
14. Disconnect the brewer from the power source.
If voltage is present as described, reinstall the level probe, the liquid level board and level probe are op- erating properly.
If voltage is not present as described, check the pink wire on the level probe from liquid level board terminal 4.
Removal and Replacement:
1.Remove all wires from the liquid level board.
2.Remove the
3.Remove the
4.Remove liquid level board and discard.
5.Install new liquid level board on component bracket and secure with a
6.Install protective shield and secure with
7.Refer to Fig. 13 and reconnect the wires.
T1 BLU to Solenoid Valve
T2 BLK to ON/OFF Switch (All models except
T3 WHI to Main Harness (120/208V, 120/240V, four wire 380V and 440V models)
T3 WHI to Transformer
(380V three wire models)
T3 RED to Main Harness (208V, 240V single phase and three phase models) T3 BLK to Main Harness (230V two wire models)
T4 PIN to Level Probe
P1733
FIG.13 LIQUID LEVEL BOARD TERMINALS