Bunn U3A service manual Remedy, TROUBLESHOOTING cont PROBLEM, Probable Cause

Models: U3A U3

1 42
Download 42 pages 23.98 Kb
Page 10
Image 10

TROUBLESHOOTING (cont.)

PROBLEM

Tank not filling

Water running out of the over- flow

PROBABLE CAUSE

1.ON/OFF Switch (This switch must be in the "ON" position for the refill circuit to operate.

2.No water

3.Solenoid Valve

4.Probe

5.Liquid Level Board

1.Brewer not level

2.Solenoid Valve

3.Liquid Level Board

4.Probe

5.Manual fill and drain valve un- derneath brewer open.

REMEDY

Refer to Service - ON/OFF Switch for testing procedures. See page 22

Be sure water shut-off is open and that in-line filters or strainers are not blocking water flow. (Do not confuse water shut-off valve with the manual fill and drain valve underneath brewer).

Refer to Service - Solenoid Valve for testing procedures. See page 27

Refer to Service - Probe for testing procedures. See page 20

Refer to Service - Liquid Level Board for testing procedures. See page 20

Brewer must be level and installed on a sturdy structure.

Refer to Service - Solenoid Valve for testing procedures. See page 27

Refer to Service -Liquid Level Board for testing procedures. See page 20

Refer to Service - Probe for testing procedures. See page 20

Be sure valve is closed.