THERMOSTAT CIRCUIT BREAKER RESET

THERMOSTAT CIRCUIT BREAKER RESET

If the Grinder suddenly stops during use, it either is overheating or has jammed. The following instructions will help get your Grinder up and running again.

STUFFER ASSEMBLY

WARNING! Before cleaning, assembling or disassembling the Grinder, make sure the PLUG IS REMOVED FROM THE OUTLET/POWER SOURCE! ALWAYS unplug the Grinder when not in use.

1.Firmly press the Power Switch Button so the Grinder is turned “off.”

2.Unplug the Power Cord from the electrical outlet.

3.Disconnect the Aluminum Tray from the Grinder Head.

4.Remove the Grinder Head from the Main Body.

5. Disassemble the Grinder Head to clear any obstruction which may have jammed the Grinder.

6.Carefully lay the Grinder onto its side with the bottom facing toward you.

Figure L

Circuit

Breaker

Reset Button

Figure H

1.

Remove the Ring Nut, Grinding Plate, Knife

and Auger from the Grinder Head before installing

the Grinder Head to the Main Body.

2.

Align the notches in the Grinder Head with the

tabs on the Main Body.

3.

Press the Grinder Head against the Motor and

rotate it counterclockwise until it locks into place

(Figure H).

 

4. Insert the Auger

 

into the Grinder Head,

 

Auger Driver end first

 

(Figure I).

7.

Press the Circuit Breaker Reset Button (Figure L)

located on the bottom of the Grinder near the Power Cord

storage cavity.

8.

Set the Grinder upright on its Feet.

9.

Re-connect the Power Cord to the electrical outlet.

10. Press the Power Switch Button to turn “on” the Grinder.

Figure I

Stomper with Lid

Tray

5.Place the Stuffing Spacer into the Grinder Head. Make sure the notch of the Stuffing Spacer fits into the positioning pin of the Grinder Head.

11. If the Grinder still does not operate, it most likely stopped due to overheating. If

this is the case, press the Power Switch Button to turn “off” the Grinder.

12. Let the Grinder to cool about 20 minutes or until it will operate again when turned “on.”

RING NUT LOOSENING WRENCH

If the Ring Nut becomes hard to remove, you can use the Ring Nut Loosening Wrench to loosen it.

DO NOT use the Ring Nut Loosening Wrench to tighten the Ring Nut. DO NOT over-tighten the Ring Nut.

Stuffing

Funnel

Front Ring

Nut

Stuffing

Spacer Grinder

Auger Head

Assembly

Auger

Driver

6.Insert the Stuffing Funnel through the Ring Nut and then onto the Grinder Head.

7.Turn the Ring Nut clockwise onto the threaded end of the Grinder Head until it touches the Stuffing Funnel. DO NOT over- tighten the Ring Nut.

8.Place the Tray on the upright part of the Grinder Head. NEVER use the Grinder without the Tray installed!

-12-

WARNING!

NEVER operate Grinder without the Tray secured in place.

To avoid serious or fatal injury, NEVER reach into any Grinder inlet.

ALWAYS use the Stomper to push food into the Grinder Head. Read & fully understand all instructions & warnings prior to use.

-9-

Page 9
Image 9
Cabela's 33-0101-C manual Thermostat Circuit Breaker Reset, Stuffer Assembly, Ring Nut Loosening Wrench, Figure L, Figure H