Cabletron Systems 2E48-27R, 2E49-27R manual Syntaxreset

Models: 2E49-27R 2E48-27R

1 160
Download 160 pages 54.63 Kb
Page 130
Image 130

Chapter 5: Local Management

Example:

 

->netstat -i

 

 

 

 

 

 

 

 

Interface + Description

MTU

Speed

Admin

Oper

MAC Addr

 

 

 

# 1

(ethernet -csmacd)

1514

10000000

up

up

0x00 0x00

0x1d 0x07 0x50 0x0e

 

 

# 2

(ethernet - csmacd)

1514

10000000

up

up

0x00 0x00

0x1d 0x07 0x50 0x0f

 

 

# 3

(ethernet - csmacd)

1514

10000000

up

up

0x00 0x00

0x1d 0x07 0x50 0x10

 

 

# 4

(ethernet - csmacd)

1514

10000000

up

up

0x00 0x00

0x1d 0x07 0x50 0x11

 

 

->netstat -r

 

 

 

 

 

 

 

 

Destination

Next-hop

 

Interface

 

 

 

 

# Default Route

DirectConnection

1

 

 

 

 

 

# 134.141.0.0

DirectConnection

2

 

 

 

 

 

# 134.141.0.0

DirectConnection

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05141-70

 

ping:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syntax:

 

ping [IP address]

 

 

 

Description:

 

The ping command generates an outbound ping

 

 

 

 

request to check the status (alive/not alive) of a

 

 

 

 

device at a specified IP address.

Options:

 

Not Applicable

 

 

 

 

Example:

 

 

 

 

 

 

 

->ping 122.144.40.10

122.144.40.10 is alive

05141-71

reset:

Syntax:reset

Description:This reset command initiates a hardware reset of the device. The reset command initializes the CPU processor, runs the onboard diagnostics, and restarts the software image, which restores the user configuration settings from NVRAM. The user will be queried to confirm the reset command to ensure against unwanted resets.