INSTALLATION

2.13 SPECIFICATIONS

2.13.1 Power Requirements

 

E1100 Series

+5 V @ ≤ 2.0 amps maximum

 

+12 V @ ≤ 500 mA maximum

 

with transceiver attached.

E2100 Series

+5 V @ ≤ 2.0 amps maximum

 

+12 V @ ≤ 175 mA maximum

 

with transceiver attached.

E3100 Series

+5 V @ ≤ 1.2 amps maximum

 

+12 V @ ≤ 175 mA maximum

 

with transceiver attached.

2.13.2 Environmental Requirements

Operating Temperature:

0° to + 60°C (32° to 140°F)

Operating Humidity:

10% to 90% (non-condensing)

2.13.3 Safety

Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC, TUV, VDE Class A. Meets FCC, Part 15, Class A limits.

2.13.4 Dimensions

 

E1100 Series

7.9 H x 11.4 W cm

 

(3.1 H x 4.5 W inches)

E2100 Series

7.9 H x 16.8 W cm

 

(3.1 H x 6.6 W inches)

E3100 Series

8.8 x 20.4 cm

 

(3.5 x 8.0 inches)