MAKING NETWORK CONNECTIONS
•Check the cable for continuity, and ensure that the cable is actually a twisted pair cable.
•Check that the adapter is properly seated in the expansion slot.
•Check that the twisted pair connection meets dB loss and cable specifications outlined in Section 3.1.2, below.
If a link still has not been established, contact Cabletron Systems Technical Support (see Section 2.12, Getting Help).
3.1.2 Twisted Pair Requirements
•Length -
NOTE: Due to cable delay, the maximum link length is always limited to about 200 meters (656 feet), regardless of the cable type.
Generally, links up to 150 meters (492 feet) long are achievable for unshielded and shielded twisted pair cable. For each connector or patch panel, subtract 12 meters (39.4 feet). This allows links of up to 126 meters (413.4 feet) using standard 24 AWG UTP wire and two patch panels. Higher quality, low attenuation cables may be required when using links greater than 126 meters.
•Insertion Loss - 11.5 dB maximum for a
•Impedance - Unshielded twisted pair cable is typically between 85 to 110 ohms. Shielded cable, such as Type 1 cable, is typically 150 ohms which can increase the signal reflection. Cabletron Systems
•Jitter - Not more than 5.0 nsec for a