Chapter 3: Installation Requirements and Specifications

3.4OPERATING SPECIFICATIONS

This section details power supply and environmental requirements.

3.4.1Power Supply Requirements

The SEH has a universal power supply. The input power requirements are listed in Table 3-2.

Table 3-2 Power Requirements

Line Input Range

Current

Frequency

 

 

 

 

 

 

100–125 Vac

4.0 A

50/60 Hz

 

 

200–250 Vac

2.0 A

 

 

 

 

3.4.2Environmental Requirements

The environmental requirements for the SEH are detailed in this section.

Operating Temperature:

5°C to 40°C

(41°F to 104°F)

Storage Temperature:

-30°C to 73°C (-22°F to 164°F)

Operating Humidity:

15% to 95% (non-condensing)

3.5AGENCY APPROVALS

The safety, emission, and immunity approvals for the SEH are detailed in this section.

3.5.1Safety

This unit meets the requirements of UL 1950, CSA C22.2 No. 950, IEC 950, and EN 60950.

3.5.2Emission

This unit is compliant with the requirements of FCC Part 15 Class A, EN 55022 Class A, and VCCI Class I.