CHN50300
Replacement Parts
Use only genuine Campbell Hausfeld
service parts.Tool performance, safety and durability could be reduced if improper parts are used.When ordering replacement parts, specify by part number.
Assembly Procedure For Seals
When repairing a nailer, the internal parts must be cleaned and lubricated. Parker
surfaces and pivots. After reassembling, a few drops of 30W
Technical Service
For information regarding the operation or repair of this product, please call
Stop using nailer immediately if any of the following problems occur. Serious personal injury could result.
Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
Symptom | cause | solution | ||
Lack of power; slow to cycle. | 1. | Tool is too dry | 1. | Add lubricant |
| 2. | Air pressure is low | 2. | Check air supply equipment |
| 3. | Exhaust is blocked | 3. | Clean exhaust |
|
|
|
|
|
Shooting no fastener or | 1. | Damaged pusher spring | 1. | Replace spring |
intermittent feeding | 2. | Wrong size fastener is being used | 2. | Use standard fasteners |
| ||||
| 3. | Magazine or wear plate is dirty | 3. | Clean magazine and nose |
|
|
|
|
|
Fastener jammed in tool | 1. | Driver channel is worn | 1. | Replace wear plate |
| 2. | Driver is broken or worn | 2. | Replace driver |
| 3. | Fasteners are bent | 3. | Use standard fasteners |
|
|
|
|
|
www.chpower.com 15