KV-2199XDK

RM-952

6.SELF-DIAGNOSTIC CIRCUIT

 

 

 

 

IC301

 

IC001

 

 

 

 

 

 

IC003

 

 

Y/CHROMA JUNGLE

 

SYSTEM

 

 

 

 

 

 

MEMORY

FROM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

IK-IN

 

 

 

IO-8DAT

45

 

 

 

5 B-DAT

CRT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FROM

 

 

 

MP/

 

 

 

O-LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[+B] Q604 C

 

18

 

 

 

51

 

 

 

 

 

 

PROTECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SDA 35

 

46 IO-SDAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[V]Q509/507

[+BÊovercurrentÊ»OCP¼]

Occurs when an overcurrent on the +B(135) line is detected by Q604. If Q604 go to ON

 

and the voltage to pin 18 of IC301 should go down when V.SYNC is more than seven

 

verticals in a period, the unit will automatically turn off.

[VerticalÊdeflectionÊstopped]

Occurs when an absence of the vertical deflection pulse is detected by Q509 and IC001

 

shut down the power supply.

[VerticalÊdeflectionÊovercurrent]

Occurs when an overcurrent on V drive line is detected by Q507. Power supply will be

 

shut down when detect this by IC001.

[WhiteÊbalanceÊfailure]

If the RGB levels* do not balance or become low level within 5 seconds, this error will be

 

detected by IC301. TV will stay on, but there will be no picture.

 

* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)

– 7 –

Page 7
Image 7
Canon KV-2199XDK service manual SELF-DIAGNOSTIC Circuit, +BÊovercurrentÊ»OCP¼