Step 1 — Complete Pre-Installation Checks

Table 3A — Physical Data, Under Ceiling Cooling Only Units

SYSTEM SIZE

018*

 

024

 

 

030

 

 

036

 

 

048

 

060

NOMINAL CAPACITY (tons)

11/2

 

2

 

 

3

 

 

3

 

 

4

 

5

NOMINAL SIZE (Btuh)

18,000

 

24,000

 

 

30,000

 

 

36,000

 

 

48,000

 

60,000

OPERATING WEIGHT (lb)

108

 

108

 

 

117

 

 

117

 

 

149

 

179

MOISTURE REMOVAL WEIGHT

4.0

 

7.3

 

 

6.0

 

 

9.0

 

 

13.0

 

14.5

(Pints/Hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FINISH

 

 

 

GM Motorhome White with Black Trim

 

 

 

REFRIGERANT

 

 

 

 

 

R-410A

 

 

 

Control (Cooling)

 

 

 

 

 

AccuRater Control

 

 

 

INDOOR FAN

 

 

 

 

 

Direct Drive Centrifugal

 

 

 

Rpm...Cfm High

862...500

 

1050…600

 

 

1275...840

 

 

1275...840

 

 

1435...1200

 

1275...1600

 

 

 

 

 

Rpm...Cfm Medium

690...400

 

690...400

 

 

972...740

 

 

972...740

 

 

1388...1160

 

972...1220

Rpm...Cfm Low

552...320

 

552...320

 

 

830...640

 

 

830...640

 

 

1315...1100

 

830...1040

High Speed Watts

92

 

92

 

 

282

 

 

282

 

 

425

 

564

Motor Quantity

1

 

1

 

 

1

 

 

1

 

 

2

 

2

Blowers — No. ...Size (in.)

2...6x8

 

2…6x8

 

 

2…6x8

 

 

2…6x8

 

 

3…6x8

 

4…6x8

INDOOR COIL

 

 

 

 

 

Copper Tube, Aluminum Fin

 

 

 

Face Area (sq ft)

2.2

 

2.2

 

 

2.6

 

 

2.6

 

 

3.0

 

4.0

 

 

 

 

 

No. of Rows

4

 

4

 

 

4

 

 

4

 

 

4

 

4

Fins/in.

14.9

 

14.9

 

 

14.9

 

 

14.9

 

 

14.9

 

14.9

Circuits

4

 

4

 

 

4

 

 

4

 

 

8

 

8

FILTERS

 

 

 

 

 

Cleanable

 

 

 

Quantity

4

 

4

 

 

5

 

 

5

 

 

6

 

8

 

 

 

 

 

AIRSWEEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

 

 

 

 

 

User select ON/OFF

 

 

 

Vertical

 

 

 

 

 

Manual

 

 

 

CONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Voltage

 

 

 

 

 

 

24 V

 

 

 

Auto Restart

 

 

 

 

 

 

Yes

 

 

 

Fan Speed

 

 

 

 

 

High/Medium/Low

 

 

 

Condensate Pump Safety

 

 

 

 

 

Yes (Accessory)

 

 

 

Indoor Coil Freeze Protection

 

 

 

 

 

Standard shutoff at 28 F

 

 

 

Filter Change Indication

 

 

 

 

 

250 Hours of Indoor Fan Operation

 

 

 

REFRIGERANT LINES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection Type

 

 

 

 

 

 

Flare

 

 

 

Liquid Line OD (in.)

 

 

 

 

 

 

3/8

 

 

 

 

 

Vapor Line OD (in.)

5/8

 

5/8

 

 

3/4

 

 

3/4

 

 

7/8

 

7/8

 

 

 

 

 

Max Line Length

 

 

For maximum

 

line lengths see

 

condensing unit

 

instructions.

 

 

CONDENSATE DRAIN

 

 

 

 

 

Pipe Thread (MPT)

 

 

 

CONNECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSATE DRAIN SIZE (in.)

 

 

 

 

 

 

3/4

 

 

 

 

 

*Field reconfigured to 18,000 Btuh (11/2 tons). See Before Installa- tion section on this page for details.

The valve connection size is 7/8 inch. The recommended line size is 11/8 inch.

Step 1 — Complete Pre-Installation Checks

UNPACK UNIT — Store fan coil unit in the original packag- ing until it is moved to the final site for installation. When re- moving unit from carton, lift unit by its 4 corners; DO NOT lift unit by its plastic parts.

INSPECT SHIPMENT — Upon receipt of shipment, check fan coil unit for damage. Forward claim papers directly to the transportation company. Manufacturer is not responsible for damage incurred in transit.

Check all items; if any item is missing, notify your dealer. To prevent loss or damage, leave all parts in original packages until installation.

BEFORE INSTALLATION — Perform the following steps before installing indoor fan coil unit. Place the indoor unit up- side down on the floor, then:

1.Remove side panels by sliding forward, then away from sides of unit (Fig. 2). Reinstall prior to unit start- up.

2.Remove air filters from inlet grilles; then remove and retain screws securing inlet grilles to indoor unit. Rein- stall prior to unit start-up.

NOTE: Dimensions shown in brackets [ ] are in mm.

Fig. 2 — Removal of Mounting Brackets

from Indoor Unit

3

Page 3
Image 3
Carrier 40QA024-060 specifications Complete Pre-InstallationChecks, Removal of Mounting Brackets, from Indoor Unit