1.3 DataCORDER INTERFACE
The DataCORDER is capable of performing the following functions initiated by the DataView Program
1.3.1Data Extraction a. Daily Header Data
Recorded days are presented in the following format:
1. Day 1 date (month, day, year), sensor data, events, ...
2. Day 2 date (month, day, year), sensor data, events, ...
b. Sensor Data
Sensor data will be read based on either standard or generic configuration. Please refer to separately bound manuals covering the Refrigeration Unit for further explanation of standard and generic configurations, see Table
1.3.2 Events
Events will be transmitted to the DataCORDER as specified in Table
Table 1-3. Temperature Controller Events
Event | When Event Occurs | Data Stored | Limits | |
|
|
|
| |
Set Point Change (SP) | Whenever the temperature | New set point; method | Last 1 per hour, last 6 per | |
set point changes | used to change it | day. | ||
| ||||
| Whenever a defrost cycle | Source of initiation (key- |
| |
Defrost Start (DS) | is initiated and when the | pad, communications, tim- | First 1 per hour, first 10 | |
system is in defrost mode | er, or active from previous | per day. | ||
| ||||
| at midnight | day) |
| |
Defrost End (DE) | Whenever a defrost cycle | Source of termination | Last 1 per hour, last 10 per | |
is terminated | (normal, timer, or HTT) | day | ||
| ||||
| Whenever | Source of initiation (key- | First 1 per hour, first 4 per | |
pad, communications, or | ||||
or is active at midnight | day. | |||
| active from previous day) | |||
|
|
| ||
|
|
|
| |
Whenever | Pass/Fail data for each test | Last 1 per hour, last 4 per | ||
pletes. | run since last power up | day. | ||
| ||||
Dehumidification Start | Whenever dehumidifica- | Set point, humidity read- | First 1 per hour, first 10 | |
tion is initiated, or is ac- | ing type (active at mid- | |||
(DHS) | per day. | |||
tive at midnight | night or normal) | |||
|
| |||
|
|
|
| |
Dehumidification End | Whenever dehumidifica- | Set point, humidity read- | Last 1 per hour, last 10 per | |
(DHE) | tion ends | ing | day | |
Humidification Start | Whenever humidification | Set point, humidity read- | First 1 per hour, first 10 | |
is initiated, or is active at | ing, method used to cause | |||
(HS) | per day. | |||
midnight or “htESt” is run | it | |||
|
| |||
|
|
|
| |
Humidification End | Whenever humidification | Set point, humidity read- | Last 1 per hour, last 10 per | |
(HE) | ends | ing | day | |
Humidity Set Point | Whenever humidity set | New set point, method | N/A | |
Change | point changes | used to change it | ||
| ||||
| Case 1: Whenever an | Case 1: Alarms active dur- | Case 1: 1 per hour which | |
| is a combination of all | |||
| alarm changes state | ing this hour | alarm events in that hour | |
Controller Alarm |
|
| ||
|
|
| ||
Case 2: At the end of any |
|
| ||
Activity (AL) |
|
| ||
hour where an alarm active | Case 2: Currently active | Case 2: 1 per hour | ||
| ||||
| during that hour is inactive | alarms | ||
|
| |||
| at the end of the hour |
|
| |
|
|
|
| |
Controller S/W Upgrade | Any change in the Con- | New software version | Last 1 per day. | |
| troller software revision. |
|
| |
Container ID Change | Any time the container ID | New ID | Last 1 per day | |
is changed | ||||
|
|
|