Table
Event |
|
| When Event Occurs |
| Data Sent |
| Limits |
Trip Start (TS) |
| Any time trip start is en- | NA |
| NA | ||
| tered |
| |||||
|
|
|
|
|
| ||
USDA Trip Comment |
| When entered with | Up to 80 bytes of custom- |
| Last 1 per day | ||
| interrogation device | er comment data |
| ||||
|
|
|
| ||||
|
| Any time a | Pass/Fail for each |
|
| ||
| completed and Controller | and appropriate data points |
| Unlimited | |||
| is configured to send indi- |
| |||||
|
| for each test |
|
| |||
|
| vidual test data |
|
| |||
|
|
|
|
|
| ||
Economy Mode Start |
| Any time economy mode | NA |
| NA | ||
(ECON_S) |
| is initiated |
| ||||
|
|
|
|
| |||
Economy Mode End |
| Any time economy mode | NA |
| NA | ||
(ECON_E) |
| is terminated. |
| ||||
|
|
|
|
| |||
ISO Trip Comment |
| Whenever entered | Data entered by user |
| Last 1 per hour, last 1 per | ||
Changed |
|
| day | ||||
|
|
|
|
|
| ||
Bulb Mode Start |
|
|
| Evaporator fan speed, |
|
| |
| Any time bulb mode starts | DTT opening temperature, |
| NA | |||
(BULB_S) |
|
| |||||
|
|
| dehumidification set point |
|
| ||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Bulb Mode End |
| Any time bulb mode ends | NA |
| NA | ||
(BULB_E) |
|
| |||||
|
|
|
|
|
|
| |
Controller Configuration |
| Whenever changed by user | Configuration information |
| Last 1 per hour, last 1 per | ||
Change |
|
|
|
|
|
| day |
Operating Mode Change |
| Whenever unit changes | New operating mode |
| Last 2 per hour, last 24 per | ||
|
| mode |
|
|
| day | |
Power Management |
| Whenever power manage- |
|
|
| Last 4 per hour, last 24 per | |
Start |
| Power management mode |
| ||||
| ment starts |
| day | ||||
(Reciprocating Only) |
|
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Power Management End |
| Whenever power manage- | Method used to end power |
| Last 4 per hour, last 24 per | ||
(Reciprocating Only) |
| ment ends | management |
| day | ||
Airslide Position |
| Whenever Makeup Vent | Source of change com- |
| Last 1 per hour, last 6 per | ||
Change |
|
| |||||
| Slide Position is changed | mand |
| day | |||
(Reciprocating Only) |
|
| |||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Phase Switching |
| Whenever Phase Sequence | Phase switched to correct/ |
| Last 6 per hour, last 24 per | ||
(Scroll Only) |
| is Checked | incorrect |
| day | ||
|
|
| Table |
|
| ||
|
|
|
|
|
|
| |
Event |
| When Event Occurs |
| Data Stored |
| Limits | |
|
|
|
|
|
|
|
|
|
|
| Case 1: Whenever an |
| Case 1: Alarms active |
| Case 1: 1 per hour which |
|
|
|
|
| is a combination of all | ||
|
|
| alarm changes state |
| during this hour |
| |
|
|
|
|
| events in that hour | ||
|
|
|
|
|
|
| |
DataCORDER Alarm Ac- |
|
|
|
|
|
| |
| Case 2: At the end of any |
|
|
|
| ||
tivity (DAL) |
| hour where an alarm ac- |
| Case 2: Currently active |
| Case 2: 1 per hour | |
|
|
| tive during that hour is in- |
|
| ||
|
|
| active at the end of the |
| alarms |
|
|
|
|
| hour |
|
|
|
|
Battery Backup Start |
| Loss of main power with |
| NA |
| NA | |
(OFFWB) |
| battery pack present |
|
| |||
|
|
|
|
| |||
Battery Backup End |
| Restoration of AC power |
| NA |
| NA | |
(ONWB) |
| with battery pack present |
|
| |||
|
|
|
|
| |||
Power Loss (OFF) |
| Loss of AC power with no |
| NA |
| NA | |
|
|
| battery pack present |
|
|
|
|