Table 6.1 – Resistance Checks

Input

Meter

 

 

 

Diode

Connection

 

Component is OK if

 

No.

(+)

 

(-)

 

resistance (R) is:

Component is defective if:

 

 

 

 

 

 

 

1

*

 

SCR1

 

10 < R < 1 megohm

Continuity (short circuit) or

 

 

 

 

 

 

open when the meter is

2

*

 

SCR2

 

 

 

 

 

connected with reversed

 

 

 

 

 

 

3

*

 

SCR3

 

 

polarity.

 

 

 

 

 

 

 

 

 

 

 

4

*

 

SCR4

 

 

 

 

 

 

 

 

 

 

5

*

 

SCR5

 

 

 

 

 

 

 

 

 

 

6

*

 

SCR6

 

 

 

 

 

 

 

 

 

7

SCR1

**

 

 

 

 

 

 

 

 

 

8

SCR2

**

 

 

 

 

 

 

 

 

 

9

SCR3

**

 

 

 

 

 

 

 

 

 

10

SCR4

**

 

 

 

 

 

 

 

 

 

11

SCR5

**

 

 

 

 

 

 

 

 

 

12

SCR6

**

 

 

 

 

 

 

 

* (+) DC Bus Volts power terminal

 

** (-) DC Bus Volts power terminal

 

 

 

 

 

 

 

 

 

 

 

Table 6.1 - Resistance Checks (Continued)

 

 

 

 

 

 

Meter

 

 

 

IGBT

Connection

 

Component is OK if

 

No.

(+)

 

(-)

 

resistance (R) is:

Component is defective if:

 

 

 

 

 

 

1

*

W/T3

 

10 < R < 1 megohm

Continuity (short circuit) or

 

 

 

 

 

 

open when the meter is

2

*

V/T2

 

 

 

 

connected with reversed

 

 

 

 

 

 

3

*

U/T1

 

 

polarity.

 

 

 

 

 

 

 

 

 

 

4

W/T3

 

**

 

 

 

 

 

 

 

 

 

 

5

V/T2

 

**

 

 

 

 

 

 

 

 

 

 

6

U/T1

 

**

 

 

 

 

 

 

 

 

 

 

* (+) DC Bus Volts power terminal ** (-) DC Bus Volts power terminal

Troubleshooting the Drive

6-5

Page 23
Image 23
Carrier D2-3466-2 instruction manual Igbt