THROUGH-THE-WALL INSTALLATION
NOTE
Window installation GW 05825004 instructions come with the window accessory kit only for ZC models. It is available as an accessory for ZH and ZQ models.
6 3/4” (17 cm)
45°
12” (30 cm)
CAUTION
Good framing construction practices must be followed to ensure a safe, secure and properly installed unit.
Cut opening in wall. For dimensions see Fig. below.
Frame opening in wall. For wood framing,provide a wooden framing support or other approved structure for fastening casing to wall. See Fig. for typical wood framing.
WALL STUD | FRAME OR | |
BACK UP STRIP | ||
|
FINISHED
17 5/16”
OPENING(440mm)
DIMENSIONS
26 3/16” (665mm)
Tipical wood framing
For masonry framing, use a lintel to support wall above opening. Mouting angles are sometimes assembled to casing. Be sure to size the wall opening to provide clearance for metal thickness of casing and mouting angles if they are used. If mounting angles are to be used with casing, position angles as follows:
1.Flush with unfinished wall - plaster over or use decorative molding.
2.Against finished wall - use decorative molding.
3.Inside wall opening - use decorative molding.
15