Install the sealing tape and the flashing finishing.
NOTE
Sealing tape and flashing are not included with machine.
Positioning the cable on the power outlet side
The unit is prepared for this condition.
Install the plastic front, fastening it with two screws (one on each side).
ELECTRICAL DATA
1.All wiring must comply with local and national electrical codes. All wiring must be installed by qualified and skilled electricians. If you have any questions regarding the following instructions, contact a qualified electrician.
2.Check available power supply and solve any household wiring problems BEFORE installing and operating this unit.
3.An individual branch circuit and single receptacle used only for this air conditioner, must be available. See Table 1 for suggested wire sizes for individual branch circuit.
4.For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are note sure whether your wall outlet is properly grounded, please consult a qualified electrician.
5.The wall outlet you select must macth the plug on the unit power cord, and must be within reach of the installed unit.
NOTE
Power cord is 55 in. (1,4 m) long and extends from bottom of control panel. See Step 24, if power cord must be relocated to opposite side of unit. Do NOT use a plug adapter or extension cord.
6.Follow fuse specifications indicated on unit nameplate. See Table 2. Nameplate is located above unit control panel inside the air discharge section. For clear access to nameplate, front grille must be removed as described on page 6.
NOTE
Unit model/catalog number, service/discrete number, and serial number can be found on the nameplate. When calling for information and service, be sure to provide the service/discrete number.