Carrier ZC manual Drain System Options, 9.1DRAINING SYSTEM THROUGH THE REAR OUTLET

Models: ZC

1 28
Download 28 pages 35.17 Kb
Page 17
Image 17
9. DRAIN SYSTEM OPTIONS

IMPORTANT

If unit is installed where condensate drainage from the back of the unit can drip onto pedestrians or neighboring property, use the external drain kit supplied with the unit. See installation instructions on drain kit. - Step 9.

Hold tip angle and mark with chalk the location of screw holes to be drilled in each side of the casing for fastening in wall opening.

Drill 3 screw holes in each side of wood frame. Recheck outward tip.

NOTE 9.1DRAINING SYSTEM THROUGH THE REAR OUTLET

Chassis is heavy. Obtain help when lifting to avoid personal injury.

9. DRAIN SYSTEM OPTIONS

The conditioner comes with the two drain holes closed by plugs.

The conditioner is projected to use one of the three function options:

1)No drain connection. That way provides the most efficiency operation, but has splash noise, dripping of rain water or condensate water.

2)Rear drain, which provides a good efficiency for operation and very low splash noise, or

3)Drain pan, which captures the most condensate and does not have splash noise, but has lower efficiency operation. Both the rear drain and the drain pan can be connected to a hose and directed to a convenient location on the ground, or a suitable floor drain.

Install the draining system for the condensing water before positioning the unit in the cabinet. You must use one of the two existing systems, depending on how, and where the unit will be installed.

9.1DRAINING SYSTEM THROUGH THE REAR OUTLET

NOTE Manual background

Remove the rear plug from the unit, and install the drain (item 6, page 4).

Pass a 5/8" (15,9 mm) plastic hose through the hole located on the rear of the cabinet.

The hose must be long enough to reach the rain water drain.

17

Page 17
Image 17