Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) GUI 3-29

Network Connections

New Connection
Point-to-Point Protocol over DS0 (Serial)
PPPoDS0 (Serial) creates a connection to the Internet using a PPP tunnel over HDLC. This
configuration creates a Serial 1 connection listed on the Network Connections table. This connection
can be enabled, disabled, modified, and deleted.
NOTE: For the Adit MSR, cross-connects from Adit 600 resources (T1 lines or WAN-capable
cards) must be made before setting up the WAN link. All DS0s cross-connected to the WAN
link must be of type "Data." Use the connect (msr) command from the Adit 600 controller to
cross-connect resources to the MSR card. See the Adit 600 User Manual for more
information.
1. Select Network Connections/New Connection.
2. Select Point-to-Point Protocol over DS0 (Serial), then select Next >.
3. Add a Login User Name and Password for this Serial connection.
4. Select the Connection to be used for this WAN:
Adit 3000: Select the T1 and specify the channel range for the T1.
Adit MSR: Select the LCC.