Other: Reference altitude setting; Altitude graph; 4 display formats; Altitude differential; Altitude measurement type (0'05 or 2'00)

Bearing Sensor Precision:

Direction: Within ±10°

Values are guaranteed for a temperature range of 10°C to 40°C.

North pointer: Within ±2 digital segments

Pressure Sensor Precision:

 

Conditions

Altimeter

Barometer

 

(Altitude)

 

 

 

 

 

 

 

Fixed

0 to 6000 m

± (altitude differential 3%

± (pressure differential 3%

tempera-

 

+ 30 m) m

+ 3 hPa) hPa

ture

 

 

 

6000 to 10000 m

± (altitude differential 3%

 

 

 

+ 45 m) m

 

Effect of

0 to 6000 m

± 80 m every 10°C

± 6 hPa every 10°C

variable

 

 

 

6000 to 10000 m

± 120 m every 10°C

 

tempera-

 

 

 

 

ture

 

 

 

Values are guaranteed for a temperature range of –10°C to 40°C.

Precision is lessened by strong impact to either the watch or the sensor, and by temperature extremes.

E-143