(2) Send Command 1 to configure channel settings.
• Voltage Probe | (that is connected to CH1.) |
{1, 1, 2} → List 1_ | The first 1 is the command number, the second 1 is the |
Send (List 1)_ | channel number, and the 2 indicates use of the voltage |
| probe. |
• Temperature Probe | (that is connected to CH1.) |
{1, 1, 7} → List 1_ | The first 1 is the command number, the second 1 is the |
Send (List 1)_ | channel number, and the 7 indicates use of the temperature |
| (Celsius) probe. |
• Optical Probe | (that is connected to CH1.) |
{1, 1, 9} → List 1_ | The first 1 is the command number, the second 1 is the |
Send (List 1)_ | channel number, and the 9 indicates use of the optical probe. |
• Optional “Motion Sensor | |
{1, 4, 2} → List 1_ | 1 is the command number, 4 is the channel number |
Send (List 1)_ | (SONIC), and 2 indicates use of the motion sensor (meters). |
(3) Send Command 3 to configure measurement condition settings. | |
{3, 1, 60} → List 1_ | 3 is the command number, 1 is the sampling interval, and 60 |
| is the number of samples. |
Send (List 1)^ | You can change sampling conditions by using different |
| sampling interval and number of samples values, if you want. |
At this time, the Ready lamp lights on the
When sampling is complete, press the calculator’s wkey to restart the program.
^(Disp command) causes processing to stop until you press the wkey.
(4)Sample data from the
Receive (List 1)_ Record Time data is received and stored in List 1. Receive (List 2)_ Sampling Data of CH1 is received and stored in List 2.
English
Using the
To take 255 samples at 50∝s intervals
(1) | Send Command 0 to initialize the | |
| {0} → List 1_ | Stores {0} to List 1. 0 is the command number. |
| Send (List 1)_ | Sending List 1 executes Command 0. |
(2) | Send Command 1 to specify microphone as the channel. | |
| {1, 10} → List 1_ | 1 is the command number, and 10 indicates use of |
| Send (List 1)_ | the |
(3) | Send Command 3 to configure measurement condition settings. | |
| {3, 0.00005, 255} → | 3 is the command number, 0.00005 is the sampling interval |
| List 1_ | (50∝s), and 255 is the number of samples. |
| Send (List 1)^ | You can change sampling conditions by using different |
|
| sampling interval and number of samples values, if you want. |
At this time, the Ready lamp lights on the
When sampling is complete, press the calculator’s wkey to restart the program.
^(Disp command) causes processing to stop until you press the wkey.
(4)Sample data from the
Receive (List 1)_ Record Time data is received and stored in List 1.
Receive (List 2)_ Sampling Data of microphone is received and stored in List 2.
•When using the
from the sound source.
•If the graph shows that the sampled sound is exceeding the sampling range as shown below, either lower the volume of the sound source or move the microphone further away from the sound source.