Using the
To output sound recorded by the built-in microphone
(1) Send Command 0 to initialize the
{0} → List 1_ | Stores {0} to List 1. 0 is the command number. |
Send (List 1)_ | Sending List 1 executes Command 0. |
(2) Send Command 1 to specify microphone as the channel. | |
{1, 10} → List 1_ | 1 is the command number, and 10 indicates use of |
Send (List 1)_ | the |
(3) Send Command 3 to configure measurement condition settings. | |
{3, 0.00005, 120000} | 3 is the command number, 0.00005 is the sampling interval |
→ List 1_ | (50∝s), and 120000 is the number of samples. |
Send (List 1)^ | You can change sampling conditions by using different |
| sampling interval and number of samples values, if you want. |
At this time, the Ready lamp lights on the
When sampling is complete, press the calculator’s wkey to restart the program.
^(Disp command) causes processing to stop until you press the wkey.
(4)Send Command 0 to initialize the
{0} → List 1_ | Stores {0} to List 1. 0 is the command number. |
Send (List 1)_ | Sending List 1 executes Command 0. |
(5) After sampling is complete, use Command 1 to configure speaker settings.
{1,12, 5,10} → List 1_ 1 is the command number, 12 specifies the speaker as the
Send (List 1)_ | channel, 5 is the number of loops, and 10 specifies output of |
| values sampled by the microphone. |
(6) | |
{3,0.00005,120000} | 3 is the command number, 0.00005 is the sampling interval |
→ List 1_ | (50∝s), and 120000 is the number of samples. |
Send (List 1)^ | You can change sampling conditions by using different |
| sampling interval and number of samples values, if you want. |
(7) Press [START/STOP] to output the sound recorded with the microphone.
English
Status Request
This function can be used to fetch the current status of the
To use Status Request
{7} → List 1_ | Sends Command 7. |
|
|
Send (List 1)_ |
|
|
|
Receive (List 1)_ | Receives the status information and stores it in List 1. | ||
|
|
|
|
Line 1 | Line 2 | Line 3 | Line 4 |
Status | Error Code | Battery Condition | OS Version |
0: Standby | = O: Normal | 0 to 999 | Version No. |
(No Sample Data in | ≠ O: Error |
|
|
1: Ready | Integer: Command number | < 450: |
|
2: Sampling | Decimal Part: Parameter position | low battery |
|
3: Standby |
|
|
|
(Sample Data in | Example: 3.2 |
|
|
| Second parameter of Command 3. |
|
|
| Sampling interval value error |
|
|
Auto Setup
Auto Setup detects the
To use Auto Setup
1.Connect a probe to a channel.
2.Slide the [ON/OFF] switch to turn on power.
•This causes the Power lamp to light.
3.Press the [SET UP] key.
•This causes the Ready lamp to light.
*1 The optional “Motion Sensor