Supported Calculator Models
Connection to a supported scientific calculator is essential if you want to get the most out of your EA-200. A connected Graphic Scientific Calculator sends commands that control the EA-200 during transfer of sampled data and other operations. Transferred data can be graphed on the calculator. For details about commands, see “Using Commands” on page 1-3, and “Command Tables” on page α-1-1.
Supported Calculator ModelsALGEBRA FX Series | CFX-9850/fx-7400 Series |
| |
ALGEBRA FX 2.0 PLUS | CFX-9950GB PLUS |
ALGEBRA FX 2.0 | CFX-9850GB PLUS |
FX 1.0 PLUS | CFX-9850Ga PLUS |
FX 1.0 | CFX-9850G PLUS |
| CFX-9970G |
| fx-9750G PLUS |
| CFX-9950G |
| CFX-9850G |
| fx-7400G PLUS |
| fx-7450G |
| |
Connecting the EA-200 to a Supported CalculatorUse the special data communication cable to connect the EA-200 to a supported Graphic Scientific Calculator model.
(1)Turn off the EA-200 and the calculator.
(2)Connect one end of the special data communication cable to the scientific calculator.
(3)Connect the other end of the cable to the EA-200’s MASTER port.
•Insert the plugs as far as they will go. If you experience problems when transferring data, check to make sure that both plugs are fully inserted.
•Be sure to read the user documentation that comes with the scientific calculator you are connecting.
1-2
English
Supported Probes
A probe is a sensor that connects to the EA-200 for sampling temperature, light, and other data.
The EA-200 comes with the three probes described below.
•Voltage Probe ................... Measures voltage in the range of –10V to +10V. CH3 measures in the range of –5V to +5V.
•Optical Probe ................... Measures luminance in the range of 100 to 999.
•Temperature Probe .......... Measures temperature in the range of –20°C to 130°C.
Connecting a Probe to a ChannelA probe connects to an input/output port called a “channel.” The EA-200 has seven channels: three analog channels (CH1, CH2, CH3), one sonic channel (SONIC), one digital input/output channel (DIG I/O), a microphone channel, and a speaker channel. You can connect probes individually, or you can connect multiple probes for simultaneous sampling. You can use commands to configure the settings for the channel being used for sampling, to specify how sampled data should be handled, etc.
CH1, CH2, CH3These channels are for the probes (voltage, temperature, optical) that come bundled with the EA-200.
SONICThis channel is for connection of an optional “Motion Sensor (EA-2)”.
DIG I/OThis port is for input and output of an 8-bit binary signal in the range of 0V to 5V. This could be used, for example, to light an LED.
Built-in MicrophoneThe microphone can be used to sample sound.