Flag clear operation1. Plug the power cord into an AC outlet.

2.

Hold down <RECEIPT FEED>.

 

JOURNAL

 

FEED

 

 

 

 

REG2

X1

 

 

REG1

Z1

3.

Turn the mode switch to PGM position.

OFF

X2/Z2

 

 

RF

 

Initialization

4. Release <RECEIPT FEED>.

You should see “FFFFFFFFFF” on the display.

If 10 Fs are not shown or another character are shown, immediately set the mode switch to OFF and restart from the beginning of this procedure.

5. Press <SUBTOTAL> to complete.

PGM

RECEIPT JOURNAL

FEED FEED

After completion of flag clear, receipt is issued.

Note: After flag clear, clerk 1 is assigned automatically. So do not program clerk 1 as not assignable or not operable in PGM mode.

Init 2 operation

1.Plug the power cord into an AC outlet.

2.Hold down <RECEIPT FEED>.

3.Turn the mode switch to PGM position.

4.Release <RECEIPT FEED>.

You should see “FFFFFFFFFF” on the display.

If 10 Fs are not shown or another character are shown, immediately set the mode switch to OFF and restart from the beginning of this procedure.

JOURNAL

FEED

REG2 X1

REG1 Z1

OFF X2/Z2

RF

PGM

RECEIPT JOURNAL

FEED FEED

5. Enter “8888888888” and press <CHECK TEND> to complete.

After completion, receipt is issued.

TE-2200/2400 Dealer's Manual

19