Key function/machine feature (P3)

<CURRENCY EXCHANGE>

Description

 

Choice

Program code

Disable operation in RF/REG– mode.

a

No = 0

 

Yes = 1

 

 

 

 

 

 

 

:

Disable operation in REG2 mode.

b

No = 0

(a+b+c)

Yes = 2

 

 

 

 

 

D9

Disable operation in REG1 mode.

c

No = 0

 

Yes = 4

 

 

 

 

 

 

 

 

Always “0”

 

 

;

 

 

 

D8

Define amount symbol. (0, 1 ~ 4)

 

Significant

:

(“0” means local currency symbol.)

 

number

D7

Define foreign currency totalizer. (0, 1 ~ 4)

 

Significant

:

(“0” treats as “1”.)

 

number

D6

Rounding:

 

Significant

:

Round off = 0, cut off = 1, round up = 2

 

number

D5

Always “0”

 

 

;

 

 

 

D4

Monetary mode (0 ~ 9):

 

Significant

:

º00 = 2, º0 = 1, 0 = 0, º000 = 3

 

number

D3

Monetary symbol for decimal

a

Decimal = 0

:

Comma = 1

 

 

 

 

Comma = 0

(a+b)

Monetary symbol for separator

b

D2

Decimal = 4

 

 

 

 

 

 

 

Assigning drawer number: 0 ~ 2

 

Significant

:

(“0” means drawer 1.)

 

number (0 ~ 2)

D1

 

 

<BILL>

Description

 

Choice

Program code

Disable operation in RF/REG– mode.

a

No = 0

 

Yes = 1

 

 

 

 

 

 

 

:

Disable operation in REG2 mode.

b

No = 0

(a+b+c)

Yes = 2

 

 

 

 

 

D9

Disable operation in REG1 mode.

c

No = 0

Yes = 4

 

 

 

 

 

 

 

 

Always “00000”

 

 

;;;;;

 

 

 

D8 D7 D6 D5 D4

Receipt is issued by:

 

Significant

 

•“Receipt 1 (printer connection table)” = 0

 

:

•“Receipt 2 (printer connection table)” = 1

 

number

•“Receipt 3 (printer connection table)” = 2

 

 

D3

Always “00”

 

 

;;

 

 

 

D2 D1

70