Key function/machine feature (P3)

<RATE TAX>

Description

 

Choice

Program code

Disable operation in RF/REG– mode.

a

No = 0

 

Yes = 1

 

 

 

 

 

 

 

:

Disable operation in REG2 mode.

b

No = 0

(a+b+c)

Yes = 2

 

 

 

 

 

D9

Disable operation in REG1 mode.

c

No = 0

 

Yes = 4

 

 

 

 

 

 

 

 

Always “00”

 

 

;;

 

 

 

D8 D7

Prohibit manual entry.

 

No = 0

:

 

Yes = 2

D6

 

 

Rounding:

 

Significant

:

Round off = 0, cut off = 1, round up = 2

 

number

D5

Always “0000”

 

 

;;;;

 

 

 

D4 D3 D2 D1

<MANUAL TAX>

Description

 

Choice

Program code

Multiple validation

 

Yes = 0

:

(If “No”, only one validation printing is possible.)

 

No = 4

D11

Always “0”

 

 

;

 

 

 

D10

Disable operation in RF/REG– mode.

a

No = 0

 

Yes = 1

 

 

 

 

 

 

 

:

Disable operation in REG2 mode.

b

No = 0

(a+b+c)

Yes = 2

 

 

D9

 

 

 

Disable operation in REG1 mode.

c

No = 0

 

Yes = 4

 

 

 

 

 

 

 

 

Always “00000”

 

 

;;;;;

 

 

 

D8 D7 D6 D5 D4

High digit limitation (HDL) for manually entered unit price

 

Significant

:

(“9” means NOT allow manual entry.)

 

number

D3

Always “00”

 

 

;;

 

 

 

D2 D1

<ERROR CORRECTION/CANCEL>

Description

 

Choice

Program code

Disable operation in RF/REG– mode.

a

No = 0

 

Yes = 1

 

 

 

 

 

 

 

:

Disable operation in REG2 mode.

b

No = 0

Yes = 2

(a+b+c)

 

 

 

 

 

D9

Disable operation in REG1 mode.

c

No = 0

 

Yes = 4

 

 

 

 

 

 

 

 

Always “0000000”

 

 

;;;;;;;

 

 

D8 D7 D6 D5 D4 D3 D2

 

 

 

A range of cancellation:

 

2 = 0

:

1 Complete cancellation/2 Current receipt only

 

1 = 1

D1

These programmable options are not effective for error correction function.

66