ADVICE FOR THE INSTALLER

35

ADVICE FOR THE INSTALLER

Important

Appliance installation and maintenance must only be carried out by QUALIFIED TECHNICIANS and in compliance with the local safety standards.

Failure to observe this rule will invalidate the warranty.

Always disconnect the appliance from the electrical supply before carrying out any maintenance operations or repairs.

The walls surrounding the oven must be made of heat-resistant material.

Taking care NOT to lift the oven by the door handle.

WARNING

When correctly installed, your product meets all safety requirements laid down for this type of product category.

However special care should be taken around the rear or the underneath of the appliance as these areas are not designed orintended to be touched and may contain sharp or rough edges, that may cause injury.

To Build in the Double Oven

The appliance should be installed by a QUALIFIED INSTALLATION TECHNICIAN. The appliance must be installed in compliance with regulations in force.

The built under double oven shall be fitted under the working surface into a kitchen base unit (width and depth 60 cm) but you must ensure that it is properly ventilated.

Installation requires a compartment as illustrated and described in next chapters:

Installation "A" between Existing Side Cabinets (560 or 600 mm GAP) (figs. 28, 29, 30, 31)

Installation "B" between Side Cabinets by Removing Provious Housing (figs. 31, 32)

Installation "C" by Using Housing Unit (figs. 33, 34, 35)

CAUTION: Do not lift the double oven by the door handles.

WARNING !

We would point out that the adhesive which bonds the plastic laminate to the furniture must withstand temperatures not less than 150° C to avoid delamination.

The appliance must be housed in heat resistant units.

The walls of the units must be capable of resisting temperatures of 75° C above room temperature.