CDA DV 770 Connection the Double Oven Mains Cable, WARNING This appliance must be earthed, Earth

Models: DV 770

1 48
Download 48 pages 22.31 Kb
Page 43
Image 43
Connection the Double Oven Mains Cable

43

Connection the Double Oven Mains Cable

Important!

This oven must be connected to the mains power supply only by a suitably qualified person.

Unscrew the screws A securing the cover plate B behind the oven (fig. 40).

Remove the cover plate B.

Remove the screws C from the cable clamp (fig. 41).

Insert the mains cable (type H05RR-F or H05VV-F - 3x2,5 mm2 section) into the cable protector P.

Connect the phase and earth cables to the mains terminal connection block D.

EARTH

N NEUTRAL

LLIVE

Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw the screws C.

Refit the cover plate B and fix it with the screws A.

WARNING: This appliance must be earthed

A

B

Fig. 40

 

D

 

Green

 

&

Brown (Live)

Yellow

(Earth)

Blue (Neutral)

 

P

 

C

Fig. 41

Page 43
Image 43
CDA DV 770 manual Connection the Double Oven Mains Cable, WARNING This appliance must be earthed, Earth