42

Electrical Installation

For your safety please read the following information:

WARNING! Before effecting any intervention on the electrical parts the appliance must be disconnected from the network.

IMPORTANT: The oven must be installed in accordance with the manufacturer’s instructions. Incorrect installation, for which the manufacturer accepts no responsibility, may cause damage to persons, animals and things.

General

–  The connection to the electrical network must be carried out by qualified personnel and must be according to existing norms.

–  The appliance must be connected to the electrical network verifying above all that the voltage corresponds to the value indicated on the specifications plate and that the cables section of the electrical plant can bear the load which is also indicated on the plate.

–  The appliance can be connected directly to the mains placing an omnipolar switch with minimum opening between the contacts of 3 mm between the appliance and the mains.

–  The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point.

–  Once the appliance has been installed, the switch must always be accessible. –  If the power supply cable is damaged it must be substituted by a suitable cable.

IMPORTANT: this double oven must be connected to a suitable double pole control unit adjacent to the oven.

NO DIVERSITY CAN BE APPLIED TO THIS CONTROL UNIT.

Feeder Cable Section

Type H05RR-F or H05VV-F

230 V~ 3 x 2.5 mm2 (**)

(**) – Connection to wall-mounting distribution panel.

The connection of the appliance to the grounding unit is mandatory.

The manufacturer declines every responsability for any inconvenience resulting from the inobservance of this condition.

Page 42
Image 42
CDA DV 770 manual Electrical Installation, For your safety please read the following information, Feeder Cable Section