•DEC Switch - This is the declination switch error value set when Utilities / Calibrate Mount / DEC Switch - Cone is carried out.
•RA Switch - This is the R.A. switch error value set when Utilities / Calibrate Mount / R.A. Switch is carried out.
Utility Features
Scrolling through the MENU (9) options will also provide access to several advanced utility functions within the CGE such as; Mount Calibration, Periodic Error Correction, Hibernate as well as many others.
Calibrate Mount - In order to optimize the performance and pointing accuracy of the CGE mount, the CGE has
•Dec Switch / Cone Calibration – this procedure simultaneously records the offset error when the declination switch is found at
•R.A. Switch Calibration - this procedure records the offset error when the right ascension switch is found at
•GoTo Calibration – Goto Calibration is a useful tool when attaching heavy visual or photographic accessories to the telescope. Goto Calibration calculates the amount of distance and time it takes for the mount to complete its final slow goto when slewing to an object. Changing the balance of the telescope can prolong the time it takes to complete the final slew. Goto Calibration takes into account any slight imbalances and changes the final goto distance to compensate.
Move to Switch – Slews the telescope to locate either its R.A. or declination switches.
UTILITIES
CALIBRATE MOUNT
DEC SWITCH / CONE
R.A. SWITCH
GOTO
MOVE TO SWITCH
R.A. TO SWITCH
DEC TO SWITCH
HOME POSTION
GOTO
SET
POLAR ALIGN
PEC
PLAYBACK
RECORD
LIGHT CONTROL
FACTORY SETTING
PRESS UNDO
PRESS "0"
VERSION
GET
GOTO
HIBERNATE
TURN ON/OFF RTC
TURN ON/OFF GPS
Home Position – The telescopes "home" position is a
Polar Align- The CGE has a polar alignment function that will help you polar align your telescope for increased tracking precision and astrophotography. After performing an Auto