Appendix B - RS-232 Connection
You can control your CGE telescope with a computer via the
Communication Protocol:
Description
PC Command ASCII
Hand Control Response
Notes
Echo | Kx | X# | Useful to check communication |
Goto | B12AB, 4000 | # | 10 characters sent. B=Command, |
|
|
| 12AB=Azm, comma, 4000=Alt. If |
|
|
| command conflicts with slew limits, |
|
|
| there will be no action. |
Goto | R34AB, 12CE | # | Scope must be aligned. If |
|
|
| command conflicts with slew limits, |
|
|
| there will be no action. |
Get | Z | 12AB, 4000# | 10 characters returned, |
|
|
| 12AB=Azm, comma, 4000=Alt, # |
Get | E | 34AB, 12CE# | Scope must be aligned |
Cancel Goto | M | # |
|
Is Goto in Progress | L | 0# or 1# | 0=No, 1=Yes; "0" is ASCII |
|
|
| character zero |
Is Alignment Complete | J | 0# or 1# | 0=No, 1=Yes |
Commands below |
|
|
|
available on version 1.6 |
|
|
|
or later |
|
|
|
HC version | V | 22 | Two bytes representing V2.2 |
Stop/Start Tracking | Tx | # | |
| x = 0 (Tracking off) |
|
|
| x = 1 |
|
|
| x = 2 |
|
|
| x = 3 |
|
|
r34AB0500,12CE0500 | # |
| |
e | 34AB0500,12CE0500# | The last two characters will always | |
|
|
| be zero. |
Commands below |
|
|
|
available on version 2.2 |
|
|
|
or later |
|
|
|
b34AB0500,12CE0500 | # |
| |
z | 34AB0500,12CE0500# | The last two characters will always | |
|
|
| be zero. |
The cable required to interface to the telescope has an
64