Appendix B - RS-232 Connection

You can control your CGE telescope with a computer via the RS-232 port on the computerized hand control and using an optional RS-232 cable (#93920). Once connected, the CGE can be controlled using popular astronomy software programs.

Communication Protocol:

CGE-i communicates at 9600 bits/sec, No parity and a stop bit. All angles are communicated with 16 bit angle and communicated using ASCII hexadecimal.

Description

PC Command ASCII

Hand Control Response

Notes

Echo

Kx

X#

Useful to check communication

Goto Azm-Alt

B12AB, 4000

#

10 characters sent. B=Command,

 

 

 

12AB=Azm, comma, 4000=Alt. If

 

 

 

command conflicts with slew limits,

 

 

 

there will be no action.

Goto Ra-Dec

R34AB, 12CE

#

Scope must be aligned. If

 

 

 

command conflicts with slew limits,

 

 

 

there will be no action.

Get Azm-Alt

Z

12AB, 4000#

10 characters returned,

 

 

 

12AB=Azm, comma, 4000=Alt, #

Get RA-Dec

E

34AB, 12CE#

Scope must be aligned

Cancel Goto

M

#

 

Is Goto in Progress

L

0# or 1#

0=No, 1=Yes; "0" is ASCII

 

 

 

character zero

Is Alignment Complete

J

0# or 1#

0=No, 1=Yes

Commands below

 

 

 

available on version 1.6

 

 

 

or later

 

 

 

HC version

V

22

Two bytes representing V2.2

Stop/Start Tracking

Tx

#

Alt-Az tracking requires alignment

 

x = 0 (Tracking off)

 

 

 

x = 1 (Alt-Az on)

 

 

 

x = 2 (EQ-N)

 

 

 

x = 3 (EQ-S)

 

 

32-bit goto RA-Dec

r34AB0500,12CE0500

#

 

32-bit get RA-Dec

e

34AB0500,12CE0500#

The last two characters will always

 

 

 

be zero.

Commands below

 

 

 

available on version 2.2

 

 

 

or later

 

 

 

32-bit goto Azm-Alt

b34AB0500,12CE0500

#

 

32-bit get Azm-Alt

z

34AB0500,12CE0500#

The last two characters will always

 

 

 

be zero.

The cable required to interface to the telescope has an RS-232 male plug at one end and a 4-4 telephone jack at the other end. The wiring is as follows:

64

Page 64
Image 64
Celestron CGE925, CGE1100, CGE800, CGE1400 manual Appendix B RS-232 Connection, Communication Protocol