GENERAL INFORMATION

PYROMASTER@ UVHB26 Vent-Free Heaters

Make it a practice to have all of your gas heaters checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

This gas room heater should be installed by a

qualified installer in accordance with local building codes and with current National Fuel Gas Code.

ANSI Z223.1 .

This heater should not be installed in a confined

space unless provisions are made for adequate combustion and ventilation air.

The National Fuel Gas Code defines a confined space as "a space whose volume is less than 50 cubic feet per 1000 BTU per hour (4.83 per kw) of the aggregate input rating of all appliances installed in that space" and unconfined space as "space."

.If the area in which the heater may be operated is smaller than that defined as an "unconfined

space," provide adequate combustion and venti- lation air by one of the methods described in the

National Fuel Code, ANSI Z223.1, 1992, Section 5.3.

FOR SAFE INSTAllATION AND OPERATION

OFYOURPYROMASTERVEN~FREEROOM

HEATER PLEASE NOTE THE FOllOWING:

1.This heater gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adutts should be alerted to the hazards of the high surface temperatures of this heater and should stay away to avoid burns or ignition of clothing.

3.Children should be carefully supervised when they are in the same room as your heater.

4.Under no circumstances should this heater be modified. Parts removed for service should be replaced prior to operating this heater again.

5.Installation and any repairs to this heater should be carried out by a qualified service person. A professional service person should be contacted to inspect this heater annually.

6.Control compartments, burners and air pas- sages in this heater should be kept clean and free of dust and lint. Make sure that the gas

valve and pilot light are turned off before you attempt to clean this unit.

7.Under no circumstances should any solid fuels

(wood, coal, paper or cardboard, etc.) be used in this heater.

8.Keep the area around your heater clear of combustible materials, gasoline and other flammable vapor and liquids. This heater should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decora- tions be hung in the area of it.

9.Upon no circumstance should this Heater be

installed in a chase or used with any other mantel than the approved FPS1212 or FPS1214 mantels.

10. Do not install heater in bedroom or bathroom.

SAFETY DEVICES

Adequate combustion and ventilation air must be provided. The flow of combustion and ventilation air MUST NOT be obstructed.

Provide adequate clearances around the air opening into the combustion chamber; and ad- equate accessibility clearance for servicing and proper operation. NEVER obstruct the front open-

ing of the heater or cover the top and bottom louvres.

These heaters are equipped with a pilot system featuring an Oxygen Depletion Sensor (O.D.S.) shut-off device. All unvented heaters are required to have this system. The O.D.S. pilot will shut

down the heater when there is not enough fresh air available.