Gas Fireplace Insert
Fan Kit Installation
115 Volt, 60 Hz. 56W
The fan kit includes the following: fan, temperature sensor, speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation.
1. | Plug in the electrical cord. |
2. | Start gas fire - see lighting procedures. |
3. | Turn on fan speed control. |
4. | Wait until the unit has warmed up sufficiently to |
| activate the temperature sensor. |
Fan Removal Instructions
1.Turn off gas and electricity.
2.Remove the front glass.
3.Remove the logs.
4.Remove burner assembly and rear log support plate.
5.Remove the fan mounting nuts (2). (Fig. 13)
6.Slip off the electrical connector at the motor.
7.Lift out the fan.
8.To reinstall, reverse procedure.
5. Once fan starts, adjust speed control to desired fan |
speed. The fan will now automatically come on every |
time the fireplace is in operation. Should the fan not |
be needed simply turn off the speed control. |
The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA
Thermal Sensor is attached to burner base
Stud
Stud
Fan is installed at the back of the air intake box
Valve
C22.1 Canadian Electrical Code.
For U.S.A. installations, follow local codes and the national electrical code, ANSI/ NFPA No. 70.
Should this fan require servicing, the power supply must be disconnected. For rewiring of any replacement components refer to Figures 13 & 14.
Fan Speed Control/Junction Box
| FP1252 |
Fig. 13 | Fan location. |
| Fan |
| Temperature Sensor |
Speed | |
Control | |
Black |
|
White |
|
Ground | |
| FP394 |
Fig. 14 | Wiring diagram RN/RP. |
10 | 10002964 |