Installation Step 13

Connect Door Arm to Trolley

Follow instructions which apply to your door type as illustrated below and on page 27.

SECTIONAL Doors Only

Make sure garage door is fully closed. Pull the manual release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about 2" as shown in Figures 1, 2 and 3.

Figure 1:

Fasten straight door arm section to outer trolley with the 5/16"x1" clevis pin. Secure the connection with a ring fastener.

Fasten curved section to the door bracket in the same way, using the 5/16"x1-1/4"clevis pin.

Figure 2:

Bring arm sections together. Find two pairs of holes that line up and join sections. Select holes as far apart as possible to increase door arm rigidity.

Inner Outer

Trolley Trolley

Figure 1

 

Figure 2

 

 

 

 

 

 

Ring

Clevis Pin

 

Lock

Rope

 

 

Fastener

5/16"x1"

Washers

 

 

 

Nuts

5/16"

 

 

 

 

 

 

 

5/16"-18

 

 

 

 

 

 

Manual

 

 

 

 

Release

Door

Straight

 

 

Handle

 

 

 

Door Arm

 

 

 

Bracket

 

 

 

 

 

 

 

 

Curved

 

 

Screws

Clevis Pin

Door

 

5/16"-18x7/8"

Door Arm

 

 

 

Bracket

 

 

5/16"x1-1/4"

 

 

 

 

 

 

 

Hole Alignment Alternative

Figure 3:

If holes in curved arm are above holes in straight arm, disconnect straight arm. Cut about 6" from the solid end. Reconnect to trolley with cut end down as shown.

Bring arm sections together.

Find two pairs of holes that line up and join with screws, lock washers and nuts.

Figure 3

Lock

 

Washers

 

5/16"

 

Nuts

 

5/16"-18

Screws 5/16"-18x7/8"

Cut this end

Hardware Shown Actual Size

Nut 5/16"-18

Lock Washer 5/16"

Ring Fastener

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clevis Pin

 

 

 

 

Clevis Pin

 

 

 

 

Hex Screw

 

 

 

 

 

 

 

5/16"x1" (Trolley)

 

 

5/16"x1-1/4" (Door Bracket)

 

5/16"-18x7/8"

Proceed to Adjustment Step 1, page 28. Trolley will re-engage automatically when the opener is operated.