Char-Broil 11101706 manual Leak Testing Valves, Hose and Regulator, Danger

Models: 11101706

1 20
Download 20 pages 47.18 Kb
Page 7
Image 7
connection, do not use this regulator!

Hold coupling nut and regulator as shown for proper connection to LP cylinder valve.

6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the back-check feature in the LP cylinder valve, resulting in some resistance. An additional one-half to three-quarters turn is required to complete the connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the

connection, do not use this regulator!

Leak Testing Valves, Hose and Regulator

1.Turn control knob clockwise to closed position.

2.Be sure regulator is tightly connected to LP cylinder.

3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

4.Brush soapy solution onto areas circled below.

DANGER

Do not insert any tool or foreign object into the valve

 

outlet or safety relief valve. You may damage the valve

 

and cause a leak. Leaking propane may result in

 

explosion, fire, severe personal injury, or death.

 

WARNING

This appliance is not intended to be installed in or on a

 

boat.

This appliance is not intended to be installed in or on an

 

RV.

Never attempt to attach this appliance to the self-

 

contained LP gas system of a camper trailer or motor

 

home.

• Do not use this appliance until leak-tested.

If a leak is detected at any time, STOP and call the fire

 

department.

If you cannot stop a gas leak, immediately close LP

 

cylinder valve and call LP gas supplier or your fire

 

department!

5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and retighten connections. If leaks cannot be stopped do not try to repair. Call for replacement parts. Order new parts by giving the serial, model number and name and part number of items needed (see parts list) to the Grill Service Center at the number listed on front cover.

6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.

Page 7

Page 7
Image 7
Char-Broil 11101706 manual Leak Testing Valves, Hose and Regulator, Danger, connection, do not use this regulator