Display
Orientation
Master/Slave Mode
Reset Software
You are able to flip the LED display for easy readability in any mounting situation. To select your display angle:
1.Press <MODE/ESC> repeatedly until diS shows on the display.
2.Press <UP> or <DOWN> to select normal display mode (diS) or inverse display mode (r diS).
3.Press <ENTER>.
The Master/Slave mode allows a single Intimidator™ Spot LED 250 unit (the “master”) to control the actions of one or more Intimidator™ Spot LED 250 units (the “slaves”) without the need of a DMX controller. The master unit will be set to operate in either Automatic or
Configure the units as indicated below.
Slave units:
1.Press <MODE/ESC> repeatedly until SLAv shows on the display.
2.Press <ENTER> to accept.
3.Set the DMX address to 001.
4.Connect the DMX input of the first slave unit to the DMX output of the master unit.
5.Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit.
6.Finish setting and connecting all the slave units.
Master unit:
1.Set the master unit to operate in either Automatic or
2.Make the master unit the first unit in the DMX daisy chain.
∙Configure all the slave units before connecting the master unit to the DMX daisy chain.
∙Never connect a DMX controller to a DMX string configured for Master/Slave operation because the controller may interfere with the signals from the master unit.
∙Do not connect more than 31 slave units to the master unit.
To reset the software on the Intimidator™ Spot LED 250, do the following:
1.Press <MODE/ESC> repeatedly until rESt shows on the display.
2.Press <ENTER>. The product will reset all settings in the software to the default factory settings.
Intimidator™ Spot LED 250 User Manual Rev. 11 | Page 15 of 20 |