4.OPERATION
Control Panel
Operation
To access the control panel functions, use the four buttons located underneath the display.
|
| Button |
|
|
|
| Function | ||
|
|
|
|
|
| ||||
|
| <MODE/ESC> |
| Press to find an operation mode or to back out of the current menu | |||||
|
|
| option |
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
| <UP> |
| Press to scroll up the list of options or to find a higher value | |||||
|
| <DOWN> |
| Press to scroll down the list of options or to find a lower value | |||||
|
| <ENTER> |
| Press to activate a menu option or a selected value | |||||
Menu Map |
|
|
|
|
|
|
|
| |
Mode |
| Programming Steps |
|
| Description | ||||
|
| DMX Mode |
|
|
|
| Sets the DMX starting address | ||
|
|
|
| SLAv (Son) |
|
| Slave operating mode | ||
|
| Operation |
| NASL (SLoU) |
|
| Automatic mode, slow program | ||
|
| Modes |
| NAFA (FASt) |
|
| Automatic mode, fast program | ||
|
|
|
| NStS (SrUn) |
|
| |||
|
| Pan |
| Normal Pan |
| PAn |
|
| Normal Pan operation |
|
|
| Inverse Pan |
| r PAn |
|
| Inverse Pan operation | |
|
|
|
|
|
|
| |||
|
| Tilt |
| Normal Tilt |
| tiL |
|
| Normal Tilt operation |
|
|
| Inverse Tilt |
| r tiL |
|
| Inverse Tilt operation | |
|
|
|
|
|
|
| |||
|
|
|
| Normal |
| diS |
|
|
|
|
| Display |
| Display |
|
| Change the LCD display text position | ||
|
|
|
|
|
| ||||
|
|
| Inverse |
| r diS |
| |||
|
|
|
|
|
|
|
| ||
|
|
|
| Display |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 13CH |
|
|
| |
|
| Channel Mode |
| Mode |
|
|
| Selects the DMX personality | |
|
|
|
|
|
|
| |||
|
|
|
| 8CH |
|
| |||
|
|
|
|
|
|
|
| ||
|
|
|
| Mode |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
| Manual Pan |
| Pan 540 |
| PA54 |
|
|
|
|
|
| Pan 360 |
| PA36 |
|
| Select Pan angle range | |
|
| Range |
|
|
|
| |||
|
|
| Pan 180 |
| PA18 |
|
|
| |
|
|
|
|
|
|
|
| ||
|
| Manual Tilt |
| Tilt 270 |
| Ti27 |
|
|
|
|
|
| Tilt 180 |
| Ti18 |
|
| Select Tilt angle range | |
|
| Range |
|
|
|
| |||
|
|
| Tilt 90 |
| Ti 9 |
|
|
| |
|
|
|
|
|
|
|
| ||
|
| Reset |
| rESt |
|
|
| Resets fixture | |
|
| Load |
| LoAd |
|
|
| Load factory defaults |
Intimidator™ Spot LED 250 User Manual Rev. 11 | Page 9 of 20 |