Operation
-14- Legend 300E Spot Us er Manual Rev. 01g
Lamp Settings
From the Main Menu , highlight Fixture Settings and pr ess <ENTER> .
The lamp will not ignite if t he ambient temperature is 1 04º F (45º C) or higher.

Lamp On / Off

1) Highlight On/Off (the current setting will show).
2) To turn the lamp on or off, press <ENTER> (a pop up wi nd ow will open).
a) Selec t ON to turn the lamp on or OFF to t urn the lamp off.
b) Accept the selec ted option.

Lamp Status During

Power On

1) Highlight State/Power On (the cu rrent setting will sh ow).
2) To change the l amp status during pow er on, press <ENT ER> (a pop up window will
open).
a) Selec t ON to turn on the fi xture and the lamp si multaneously or OFF t o turn on
the fixture without turning on the lamp.
b) Accept the selec ted option.

Remote Turn Off 1) Highlight Off Via DMX (the curr ent setting will sh ow).

2) To enable/disabl e remot e turn off, press <ENTE R> (a pop up window wil l op en) .
a) Selec t YES to enable fixture tur n off f rom eit h er a DMX controller or its power
switch, or NO to turn the f ixture off only from i ts power switch.
b) Accept the selec ted option.

Lamp On if DMX Present

1) Highlight On if DMX On (the current sett ing will show).
2) To turn the lamp on when DMX is pres ent, press <ENTER> (a pop u p wi nd ow w ill
open).
a) Selec t YES to turn the lamp on if DMX signal is present, or NO to tur n the lamp
on only from the c ontrol panel.
b) Accept the selec ted option.

Lamp Off if DMX Absent 1) Highlight Off if DMX Off (the curr ent setting will sh ow).

2) To turn the lamp off when DM X is abs ent, press <ENTER > (a pop up window will
open).
a) Selec t YES to turn the lamp off if DMX signal is absent, or NO to turn the lamp
off only from the c ontrol panel.
b) Accept the selec ted option.

Fan Speed 1) Highlight Cooling Mode (the current s etting will show).

2) To change the f an speed setting, pres s <ENTER> ( a pop up window will open).
a) Selec t AUTO to allow the fixture’s contr oller to set the f an speed, or HIGH to set
the fan speed to high mode.
b) Accept the new s election.

Lamp Strike Delay

1) Highlight Ignition Delay (the current sett ing will show).
2) To set the lamp s trike delay, press < ENTER> (a pop up window will open).
a) Select the delay befo re t he lamp strikes after power up in s econds (0~255).
b) Accept the new val ue.

Fixture Shut Off Delay

1) Highlight Low Power Delay (the curr ent setting will show ).
2) To set the lamp s hut off delay, press <ENTER> ( a pop up wi nd ow wil l op en).
a) Selec t the delay before the fixture p owers off after lamp off in seconds (0~ 255).