The CP Compressors should never be operated beyond its capabilities or in any way which does not comply with the instructions contained in this operating and maintenance guide.
Chicago Pneumatic Compressors will decline any responsibility
if these instructions are not respected.
This equipment has been factory tested and satisfies normal
operating conditions: they must not be exceeded
as this would place the machine under abnormal stress and effort.
INSTALLATION INSTRUCTIONS
For the guarantee to be valid, the unit must be assembled in covered premises with temperatures not exceeding :
Mini: + 36 °F (frost free)
Maxi: + 104 °F
You must also have:
1 meter space around the compressor
-
low ventilation (fresh air) proportionate to the ventilation flow necessary for the machine and protected
from any infiltration of humidity (splashes of water during bad weather) and all pollution
-
top insulation or extraction to ensure reversal of the flow of warm air and evacuation of the heat to
outside the equipment room
-
a link from the condensation water evacuation pipe to the drain discharger
-
in dusty environment,
on the machine's ventilation inlets
TECHNICAL DATA
VARIABLE SPEED MACHINES
CPVS Model |
|
|
| 40 |
|
|
| 50 |
|
|
| 60 |
|
|
| 75 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
VERSION CPVS (as per ISO 1217 ed 1996) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Nominal pressure at full flow | PSI |
| 58 | 102 | 138 |
| 58 | 102 | 138 | 58 | 102 | 138 | 58 | 102 | 138 | ||
Actual flow* | cfm |
| 195.1 | 194.5 | 166.4 |
| 239.1 | 234.1 | 204.4 | 291.2 | 280.2 | 244.7 | 374.3 | 342.3 | 304.8 | ||
Motor power | hp |
|
| 40 |
|
|
| 50 |
|
|
| 60 |
|
|
| 75 |
|
Ø Pressure outlet (F) | NPT |
|
| 1.5" |
|
|
| 1.5" |
|
|
| 1.5" |
|
|
| 1.5" |
|
Capacity | gal |
|
| 5,8 |
|
|
| 5,8 |
|
|
| 5,8 |
|
|
| 5,8 |
|
Carryover | ppm |
|
| 3 |
|
|
| 3 |
|
|
| 3 |
|
|
| 3 |
|
Noise level at 3,3ft | dB(A) |
|
| 65 |
|
|
| 66 |
|
|
| 67 |
|
|
| 70 |
|
(according to ISO 2157 + 3db(A)) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
* Suction pressure : 14.5 PSI absolute - Relative humidity : 0 % - Ambient temperature : 68 °F |
|
|
|
|
|
| |||||||||||
- Effective delivery pressure : 102 PSI, 109 PSI, 138 PSI or 181 PSI (effective) |
|
|
|
|
|
|
|
|
| ||||||||
Dimensions (in) | L x Wx H |
| 75x37,4x69,3 |
| 75x37,4x69,3 |
| 75x37,4x69,3 |
| 75x37,4x69,3 | ||||||||
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Approximate weight | lbs |
|
| 1874 |
|
|
| 1995 |
|
|
| 2226 |
|
|
| 2679 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
01/2008 | Chicago Pneumatic Compressors |
Page 2 | 62 305 258 65 |