F - Electric cabling
Each CPVS is wired for a
NEVER OPERATE THE CPVS ON A VOLTAGE OTHER THAN THAT SHOWN ON THE ELECTRIC CABINET.
The electric current supply to the CPVS must comply with the following table :
Type of cable to be used :
Power cable size
(for a maximum 32.8 ft length)
CPVS Model | VOLTAGE | |
| ||
460 V | ||
| ||
|
| |
40 | AWG4 | |
50 | AWG3 | |
60 | AGW1 | |
75 | AWG0 |
SAFETY REGULATIONS
It should be remembered that safety regulations require :
•An earth socket to be used.
•A manual isolating switch, cutting all three phases ; this switch must be clearly visible near the CPVS unit.
•The electric current must be cut whenever maintenance work is carried out on the machine (except for pressurized oil change)
| Fuses to be used for |
CPVS Model | the isolating switch (RK5 type) |
| |
| 460 V |
|
|
40 | 80 |
50 | 100 |
60 | 125 |
75 | 150 |
|
|
Chicago Pneumatic Compressors | 01/2008 |