F - Electric cabling

Each CPVS is wired for a pre-determined voltage, i.e. 460 V.

NEVER OPERATE THE CPVS ON A VOLTAGE OTHER THAN THAT SHOWN ON THE ELECTRIC CABINET.

The electric current supply to the CPVS must comply with the following table :

Type of cable to be used :

Power cable size

(for a maximum 32.8 ft length)

CPVS Model

VOLTAGE

 

460 V

 

 

 

40

AWG4

50

AWG3

60

AGW1

75

AWG0

SAFETY REGULATIONS

It should be remembered that safety regulations require :

An earth socket to be used.

A manual isolating switch, cutting all three phases ; this switch must be clearly visible near the CPVS unit.

The electric current must be cut whenever maintenance work is carried out on the machine (except for pressurized oil change)

 

Fuses to be used for

CPVS Model

the isolating switch (RK5 type)

 

 

460 V

 

 

40

80

50

100

60

125

75

150

 

 