Reference Manual

Wireless FuzzyScan

Configure Your FuzzyScan

Symbology Reading Control

Readable Bar Code Setting

 

PROGRAM

 

 

F_DEFAULT

 

 

 

 

 

 

Family Code Selection

P.C

Parameter Selection

Option Code

 

 

 

 

 

 

Readable Symbology Setting

SS

Auto ￿

00

 

 

 

 

 

 

CS

Code 128 *

01

 

 

CS

UPC-A *

02

 

 

CS

UPC-E *

03

 

 

CS

EAN-13 *

04

 

 

CS

EAN-8 *

05

 

 

CS

Codabar/NW-7 *

06

 

 

CS

Code 39 *

07

 

 

CS

Trioptic Code 39

47

 

 

CS

Standard/Industrial 2 of 5

08

 

 

CS

Matrix 2 of 5

38

 

 

CS

Interleaved 2 of 5 *

48

 

 

CS

China Postal Code

58

 

 

 

 

CS

German Postal Code

68

 

 

CS

Code 93 *

09

 

 

CS

Code 11

10

 

 

CS

MSI/Plessey

11

 

 

CS

UK/Plessey

12

 

 

CS

Telepen

13

 

 

 

 

CS

GS1 DataBar (RSS-14) *

14

 

 

CS

IATA

15

 

 

CS

PDF417/Micro PDF417

17

 

 

CS

Codablock F

18

 

 

CS

Korea Post Code

21

 

 

 

 

 

￿If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.

￿Above symbologies marketed with * are enable as default. When you select “Auto”, the scanner only read those symbologies marked with *

￿When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.

21