Reference Manual

Wireless FuzzyScan

Configure Your FuzzyScan

Operation Control

Time-out Setting, Good Read Duration

PROGRAM

 

 

F_DEFAULT

 

 

 

 

Family Code Selection

P.C

Parameter Selection

Option Code

Light Source On Time

SS

Short ￿

0

 

 

 

 

SS

Medium

1

 

SS

Long

2

 

SS

Extremely long

3

 

 

 

 

Hands Free Time-out

SS

Short ￿

0

 

 

 

 

SS

Medium

1

 

SS

Long

2

 

SS

Extremely long

3

 

SS

Disable

4

 

 

 

 

Good Read Duration

SS

Short

0

 

Medium ￿

 

 

SS

1

 

SS

Long

2

 

SS

Extremely long

3

 

SS

Extremely short

4

 

 

 

 

Time Delay to Low Power Trigger

SS

1 sec

0

 

 

 

 

SS

3 secs

1

 

SS

5 secs

2

 

SS

7 secs

3

 

SS

9 secs

4

 

SS

Immediate ￿

5

￿The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.

￿The Presentation Mode is referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any trigger operation), the imager will revert to the original hands free mode.

￿The Time Delay to Low Power Trigger sets the time for scanner to enter low power trigger mode after any scanning activity.

54