Reference Manual

Wireless FuzzyScan

Configure Your FuzzyScan

Operation Control

Out-of-range Scanning, Sleep Time-out Control

 

PROGRAM

 

 

F_DEFAULT

 

 

 

 

 

 

Family Code Selection

P.C

Parameter Selection

Option Code

 

Out-of-range Scanning

SS

Disable ￿

0

 

 

 

 

 

 

SS

Enable

1

 

 

 

 

 

 

Link Supervision Time-out

SS

1 sec

0

 

 

3 secs ￿

 

 

 

SS

1

 

 

SS

5 secs

2

 

 

SS

7 secs

3

 

 

SS

9 secs

4

 

 

 

 

 

 

 

 

Only available in PAIR & PICO modes

 

 

 

 

 

 

 

Sleep Time-out of Connect State

SS

6 (x5) minutes ￿

FIN

 

 

 

 

 

 

MS

0-99 (x5) minutes

(2 digits)

 

 

 

 

 

 

 

 

If you don’t want the scanner to enter sleep mode, please set time-out to “0”

 

 

 

 

 

 

 

Sleep Time-out of Disconnect State

SS

1 minute ￿

FIN

 

 

 

 

 

 

MS

0-99 minutes

(2 digits)

If you don’t want the scanner to enter sleep mode, please set time-out to “0”

￿Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to continue scanning barcode data into memory buffer until radio link resumed.

￿The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.

￿The Sleep Time-out Control can be set under radio connection or disconnection state. If the scanner is not used within the preset time-out duration, it will automatically enter “Sleep State” for power saving purpose. You are able to disable this function by setting the time-out duration to “0”.

57