Cisco Systems 15.3.00P1 Installing the WANDEST Server Patch, Installing the WANDEST Client Patch

Models: 15.3.00P1

1 50
Download 50 pages 31.51 Kb
Page 45
Image 45
Installing the WANDEST Server Patch

Installing WANDEST 2.7.00, Patch 1

Installing the WANDEST Server Patch

Use this procedure to install the WANDEST Server patch.

Confirm that the WANDEST Client has been stopped before installing patches on the WANDEST server.

Step 1 Log in to the CWM as an “svplus” user.

Step 2 Stop the core.

Step 3 Run the /usr/users/svplus/scripts/get_dbschema.ksh:

#cd /usr/users/svplus/scripts

#./get_dbschema.ksh

Awd_dbschema_tmpl file is created in the /usr/users/svplus/tmp directory. Edit this file and un-comment out the tables that you want triggers in it.

Step 4 Switch to root (for example, su):

#su

Step 5 Download or copy the compressed tar file to the local directory, for example, /tmp:

# cp wandest2.7.00-P1.wdserver.tar.gz /tmp

Step 6 Change to the local directory that contains the compressed tar files:

# cd /tmp

Step 7 Remove the disk1 directory:

# rm -rf disk1

Step 8 Decompress the compressed tar file and untar the tar file:

#gunzip wandest2.7.00-P1_wdserver.tar.gz

#tar -xvfp wandest2.7.00-P1_wdserver.tar

Step 9 Run the installation script to install the patch:

# ./InstallWDS27Patch1.csh

Step 10 Exit from root.

Step 11 Perform a coldstart:

#coldstart

Step 12 Open a new terminal to start the core.

Installing the WANDEST Client Patch

Use this procedure to install the WANDEST Client patch.

Step 1 Log in to the WANDEST client as user root.

Step 2 Download or copy the compressed tar file for WANDEST client to a local directory; for example, /tmp:

# cp wandest2.7.00-P1_wdclient.tar.gz /tmp

 

 

Release Notes for the Cisco WAN Manager, Release 15.3.00 P1

 

 

 

 

 

 

 

OL-11190-01, Rev. C0

 

 