Figure 3-16 DC Power Connections

Chapter 3 Installing the Router

Power Connections

Warning The illustration shows the DC power supply terminal block. Wire the DC power supply as illustrated. The proper wiring sequence is ground to ground, positive to positive, and negative to negative. The ground wire should always be connected first and disconnected last. Statement 239

Caution Do not overtorque the terminal block contact screws. Recommended torque is 8.0 ± 0.5 in-lb (0.9 ± 0.05 N-m).

Figure 3-16 DC Power Connections

 

-DC, input A

 

Return, input A

 

Safety ground

 

Return, input B

 

-DC, input B
A +

+ B

A +

+ B

Return, input A +DC, input A Safety ground +DC, input B Return, input B

-DC, input AReturn, input A Terminal block

Negative DC input
Safety ground Terminal block
Positive DC input
95967

Step 6 Install the plastic cover over the terminals. (See Figure 3-17.)

Warning The safety cover is an integral part of the product. Do not operate the unit without the safety cover installed. Operating the unit without the cover in place will invalidate the safety approvals and pose a risk of fire and electrical hazards. Statement 117

Step 7 Organize and secure the wires using cable ties as shown in Figure 3-17.

Step 8 Turn on power to the DC circuit.