DC Wiring Requirements for Cisco 3745 Routers

Chapter 3 Installing the Router

Power Connections

DC Wiring Requirements for Cisco 3745 Routers

A Cisco 3745 router with a DC-input power supply requires copper wire for the power connections. Table 3-2summarizes the wiring requirements.

Note Two types of DC input power supply can be installed in a Cisco 3745 router: power supplies rated at 24/48 VDC nominal input, and power supplies rated at 48 VDC nominal input. Table 3-2summarizes the wiring requirement for both power supplies.

Table 3-2

DC Wiring Requirements for Cisco 3745 Routers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Input Wire

Safety Ground

 

Overcurrent

Installed Power Supply

 

DC Input

Size

Wire Size

Wire Terminal (Lug)

Protection

 

 

 

 

 

 

 

 

 

 

Nominal 24/48 VDC1

 

 

24–36 V,

AWG 12

AWG 12

Amp/Tyco No.

20 A

Identified by the following printed

15 A

(3.0 mm2)

(3.0 mm2),

52961 or equivalent

maximum

 

 

minimum

 

 

label:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36–60 V,

AWG 12 or 14

AWG 12

For AWG 12:

20 A

CISCO 3745

 

 

7 A

(3.0 or 2.0 mm2)

(3.0 mm2),

Amp/Tyco No.

maximum

 

 

 

 

minimum

52961 or equivalent

 

100-240V~50/60Hz 10A

 

!

 

 

 

OR Input +/- 24-36 V

 

15 A

 

 

 

For AWG 14: Molex

 

36-60 V

 

7 A

 

 

 

 

 

 

 

 

 

 

No. 19099-0017 or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equivalent

 

 

 

 

 

 

 

 

 

 

 

Nominal 48 VDC2

 

 

48–60 V,

AWG 14 or 16

AWG 14

For AWG 14 or 16:

20 A

Identified by the following printed

10 A

(2.0 or 1.2 mm2)

(2.0 mm2),

Molex No.

maximum

 

 

minimum

19099-0017 or

 

label:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equivalent

 

 

 

 

 

 

 

 

 

 

 

CISCO 3745

 

!

 

 

 

 

 

100-240V~50/60Hz, 10A

 

 

 

 

 

 

 

 

 

 

 

OR 48-60V

 

, 10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.The input voltage tolerance limits for nominal 24/48-V power supplies are 18 and 72 VDC.

2.The input voltage tolerance limits for nominal 48-V power supplies are 38 and 72 VDC.

Wiring Procedure for DC Input

To connect the router to a DC power source, perform the following steps:

Step 1 Remove power from the DC circuit. To ensure that power is removed from the DC circuit, locate the circuit breaker for the DC circuit, switch the circuit breaker to the OFF position, and tape the circuit-breaker switch in the OFF position.

Tip Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.

Step 2 Strip the wires to the appropriate length for the terminals. The strip length is 1/8 to 3/16 inch (3 to 5 mm) for Molex number 19073-0009 terminals and for AMP/Tyco number 52961 terminals.

Step 3 Crimp the terminals onto the DC power input wires.

Cisco 3700 Series Routers Hardware Installation Guide

3-18

OL-2180-08

 

 

Page 64
Image 64
Cisco Systems 3700 Series manual DC Wiring Requirements for Cisco 3745 Routers, Wiring Procedure for DC Input, 3-18