show controller serial 5/0/2 Serial5/0/2 -

Framing is c-bit, Clock Source is Line

Bandwidth limit is 44210, DSU mode 0, Cable length is 10 rx FEBE since last clear counter 0, since reset 0

Data in current interval (807 seconds elapsed):

0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation

0 P-bit Err Secs, 0 P-bit Sev Err Secs

0 Sev Err Framing Secs, 306 Unavailable Secs

500 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs Data in Interval 1:

0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation

0 P-bit Err Secs, 0 P-bit Sev Err Secs

0 Sev Err Framing Secs, 0 Unavailable Secs

564 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs Data in Interval 2:

0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation

0 P-bit Err Secs, 0 P-bit Sev Err Secs

0 Sev Err Framing Secs, 0 Unavailable Secs

564 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs Data in Interval 3:

0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation

0 P-bit Err Secs, 0 P-bit Sev Err Secs

0 Sev Err Framing Secs, 0 Unavailable Secs

562 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs Data in Interval 4:

0 Line Code Violations, 0 P-bit Coding Violation 0 C-bit Coding Violation

0 P-bit Err Secs, 0 P-bit Sev Err Secs

0 Sev Err Framing Secs, 0 Unavailable Secs

560 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs

.

.

.

Total Data (last 44 15 minute intervals):

 

 

 

 

0

Line Code Violations, 0

P-bit Coding Violation,

 

 

 

 

0

C-bit Coding Violation,

 

 

 

 

 

 

0

P-bit Err Secs, 0 P-bit Sev Err Secs,

 

 

 

 

0

Sev Err Framing Secs, 0

Unavailable Secs,

 

 

 

 

24750 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs

 

 

 

Transmitter is sending AIS.

 

 

 

 

 

Receiver has loss of signal.

 

 

 

 

 

40434 Sev Err Line Secs, 0

Far-End Err Secs, 0 Far-End Sev Err Secs

0

P-bit Unavailable Secs, 0 CP-bit Unavailable Secs

0

CP-bit Far-end Unavailable Secs

0

Near-end path failures, 0 Far-end path failures

 

 

 