9
Troubleshooting Cisco 2800 Series Routers
OL-5789-01
System Messages
— — Error:
%ENVMON-3-FAN_FAILED: Fan fan-number not rotating.
Explanation:
The specified fan (1, 2, or 3) is not rotating at the desired speed.
Recovery:
Make sure that the fan power cable is properly attached to the mainboard fan power connector.
If the problem persists, contact your technical support representative.
AUX/
PWR
Amber Message:
%ENVMON-5-48V_STATUS: -48V supply failed
Explanation:
The –48 V power supply has failed.
Recommended action:
Replace the power supply. Refer to the “Replacing the Power Supply” section of theInstalling
and Upgrading Internal Modules in Cisco 2800 Series Routersonline document.
AUX/
PWR
Green Message:
%ENVMON-5-48V_STATUS: -48V supply OK
Explanation:
The –48 V power supply is operating normally.
Recommended action:
Message is informational only.
— — Message:
%ENVMON-5-RPS: Redundant power supply attached
Explanation:
Redundant power supply was connected to the router.
Recommended action:
Message is informational only.
Note The Cisco 2801 does not support RPS. This message is not applicable to the Cisco2801.
— — Message:
%ENVMON-5-RPS: Redundant power supply removed
Explanation:
Redundant power supply was disconnected from the router.
Recommended action:
Message is informational only.
Note The Cisco 2801 does not support RPS. This message is not applicable to the Cisco2801.
Table3 System Error and Recovery Messages (continued)
LED Type LED Color Message, Meaning, and Recommended Action