5
Cable Connection Procedures for Cisco2800 Series Routers
OL-5787-02
Power Connections
Figure1 DC Power Connections for Cisco 2800 Series Routers
Step6 Install the plastic covers over the terminals. (See Figure2 or Figure 3.)
Warning

The safety cover is an integral part of the product. Do not operate the unit without the safety cover

installed. Operating the unit without the cover in place will invalidate the safety approvals and pose

a risk of fire and electrical hazards.

Statement 117

Step7 Organize and secure the wires using cable ties as shown in Figure2 or Figure 3. Make sure that the wi res
do not project above or below the front panel of the router.
Step8 Turn on power to the DC circuit. Be sure to remove tape used to secure the circuit-breaker switch in the
OFF position.
Figure2 Wire Routing and Attachment for Cisco 2811 Routers
95967
A+B

+

A++B
Terminal
block
Negative DC input Positive DC input
Terminal
block
-DC, input B
Return, input B
Safety ground
Return, input A
-DC, input A
Return, input B
+DC, input B
Safety ground
+DC, input A
Return, input A
111814
From DC
power
source
Cable tie
A B
-
+ +
-
Plastic covers
24-60V --- 8A