C H A P T E R 3

Specifications

This chapter details the Server Switch Module specifications.

Electrical Requirements

Table 3-1

DC Supply Requirements

 

 

 

 

Area

 

Requirement

 

 

DC Supply Voltage

12.2 Volts nominal

 

 

DC Supply Current

6.0 Amps maximum

 

 

DC Supply Power without External Port Powered Devices

39 watts maximum

 

 

DC Supply Power with External Port Powered Devices

60 watts maximum

 

 

 

Note External port powered devices are limited to 21 watts total.

Environmental Requirements

 

 

Table 3-2

Environmental Requirements

 

 

 

 

 

 

 

Area

 

Requirement

 

 

 

 

 

 

Module Operating Temperature

0 to +60 degrees C (module inlet)

 

 

 

 

 

 

Forced Air Cooling: Rate

6.5 CFM minimum

 

 

 

 

 

 

Module Non-Operating Temperature

-40 to +70 degrees C

 

 

 

 

 

 

Operating Altitude

0 to 2133 meters

 

 

 

 

 

 

Non-Operating Altitude

0 to 11,000 meters

 

 

 

 

 

 

Operating Humidity

5% to 85% non-condensing

 

 

 

 

 

 

Non-Operating Humidity

5% to 95% non-condensing

 

 

 

 

 

 

Operational Shock

3.5G for 3 mSec.

 

 

 

 

 

 

 

 

 

 

 