Removing and Installing Modules in the Chassis

Vertical slots

a.Position the module in the slot. (See Figure 26.) Make sure that you align the sides of the module carrier with the slot guides on the top and bottom of the slot.

b.Carefully slide the module into the slot until the EMI gasket along the right edge of the module makes contact with the module in the slot adjacent to it and both ejector levers have closed to approximately 45 degrees with respect to the module faceplate. (See Figure 27.)

c.Using the thumb and forefinger of each hand, grasp the two ejector levers and exert a slight pressure to the left, deflecting the module approximately 0.040 inches (1 mm) to create a small gap between the module’s EMI gasket and the module adjacent to it. (See Figure 27.)

Caution Do not exert too much pressure on the ejector levers. They will bend and be damaged.

d.While gently pressing on the ejector levers, simultaneously close them to fully seat the module in the backplane connector. The ejector levers are fully closed when they are flush with the module faceplate. (See Figure 28.)

e.Tighten the two captive installation screws on the module.

Note Make sure that the ejector levers are fully closed before tightening the captive installation screws.

f.Verify that the module STATUS LED is lit. Check the STATUS LED periodically. If the STATUS LED changes from orange to green, the module has successfully completed the boot process and is now online. If the STATUS LED remains orange or turns red, the module has not successfully completed the boot process and may have encountered an error.